GetFRP
STANDARD REFERENCE

ASTM D7957 GFRP Rebar Specification: Requirements and Evidence

What ASTM D7957 covers, its 44.8 GPa modulus and 70% fiber minimums, how it fits with ACI 440.11, ICC-ES AC454, CSA S807 and ASTM D8505, and what test evidence to request from GFRP rebar suppliers in China.

Short answer

ASTM D7957/D7957M is the US material specification for solid round glass fiber reinforced polymer (GFRP) bars used to reinforce concrete, supplied straight or as factory-bent shapes with a surface enhancement for bond. It requires at least 70% fiber by mass and a tensile modulus of at least 44.8 GPa (6,500 ksi), sets size-specific strength requirements and limits on properties such as glass transition temperature, moisture absorption, degree of cure, transverse shear, bond and alkali resistance. ACI CODE-440.11-22 accepts only vinyl ester bars that conform to D7957. Compliance is shown by a test report on the bars being bought; D7957 is not a certification scheme.

Editions: D7957/D7957M-17 was replaced by the -22 edition in 2022, and a -25 edition has been published. Datasheets still commonly cite -22; confirm which edition the project specification names. Reviewed by GetFRP on .

Scope

  • Solid round GFRP bars for concrete reinforcement, straight or bent, with an external surface enhancement (sand coating, helical wrap or ribs) for bond.
  • Material requirements: fiber content of at least 70% by mass and a minimum tensile modulus of 44.8 GPa (6,500 ksi).
  • Size-specific requirements for tensile strength, so a report must state the bar sizes tested.
  • Physical and durability limits, including glass transition temperature, moisture absorption, degree of cure, transverse shear, bond and alkali resistance after high-pH conditioning.
  • Not covered: hollow bars and non-glass reinforcement such as carbon; higher-strength glass and basalt bars fall under ASTM D8505, and structural design under ACI CODE-440.11-22 and the AASHTO GFRP guide specification.

Where ASTM D7957 sits among GFRP rebar specifications

Where ASTM D7957 sits among GFRP rebar specifications
DocumentRoleMinimum modulus
ASTM D7957/D7957MMaterial specification for solid round GFRP bars44.8 GPa (6,500 ksi); fiber at least 70% by mass
ASTM D8505/D8505MMaterial specification for higher-strength glass and basalt barsHigher-modulus tier; see the standard
CSA S807 Grade I / II / IIICanadian material specification with modulus grades40 / 50 / 60 GPa
ACI CODE-440.11-22US building code for GFRP-reinforced concrete; adopted by the 2024 IBCRequires vinyl ester bars conforming to D7957
ICC-ES AC454 / AC521Product evaluation route for structural / non-structural useValues reported per product

Source: GetFRP global GFRP rebar market research: vendor summary of ASTM D7957 (Jivial Composite), FDOT presentation of CSA S807 grades, PCI Journal on ACI 440.11 scope, ICC-ES reports.

Compliance means a lot-level test report

A website claim of "compliant with ASTM D7957" is not evidence. The specification defines properties and test methods; it does not certify a plant. Ask for a recent report on the bar sizes you are buying, from a named laboratory, linked to the production lot.

Some export catalogues list a tensile modulus below the 44.8 GPa minimum while claiming D7957 compliance, and tensile strength falls with bar diameter: one exporter datasheet shows 1,100 MPa at 6 mm against 675 MPa at 25 mm. Check every bar size, not the best one.

Code and approval routes in North America

ACI CODE-440.11-22 is the first mandatory-language ACI building code for GFRP-reinforced concrete, adopted by reference in the 2024 International Building Code. It limits scope to solid round vinyl ester bars conforming to D7957 and restricts use by seismic design category.

Private US building work usually needs an ICC-ES evaluation report under AC454 (structural) or AC521 (non-structural), or an engineer's acceptance of D7957 test evidence. Canadian work uses CSA S807 certification; state highway work uses DOT production-facility lists. The AASHTO bridge guide specification is moving to add ASTM D8505 alongside D7957.

What this means for GFRP rebar from China

GetFRP found no Chinese-owned producer with a structural ICC-ES (AC454) report, a CSA S807 certification listing or a published Grade III (60 GPa) bar. One China-sited plant owned by the foreign group Dextra holds a non-structural AC521 report (ESR-5501).

Chinese bars can be good value for D7957-based work when the buyer controls the evidence: modulus and strength by bar size, fiber content, resin type (vinyl ester for ACI 440.11), alkali resistance and bend strength for bent shapes.

How to cite it in an RFQ

  1. Name the edition (D7957/D7957M-22 or -25) and confirm whether the project requires ACI 440.11, ICC-ES, CSA S807 or a DOT listing.
  2. Request test reports for every bar size ordered: tensile strength and modulus, plus fiber content.
  3. Confirm the resin is vinyl ester where ACI 440.11 applies.
  4. Ask for the alkali-resistance, glass transition, degree-of-cure, moisture absorption, transverse shear and bond results the specification requires.
  5. For bent shapes, require bend strength results: factory-bent thermoset bars can retain as little as 25% of straight-bar strength.
  6. Tie reports to the production lot and plant, and name the laboratory and report holder.
Send a standards-based RFQ

Sources

Requirements are paraphrased from public sources; the purchased standard text controls. See the editorial methodology.

Buying notes and qualification boundaries

ASTM D7957 should be cited with its edition and the project's acceptance route. A supplier statement that a bar is "to D7957" is not enough unless the offered sizes, resin and lot-linked test values align with the document.

GetFRP lists reviewed Chinese supplier profiles that cite ASTM D7957 below. A citation is a discovery signal, not a qualification.

PUBLIC SUPPLIER RECORDS

Matching supplier profiles

Each row shows the terms its public profile mentions. A match is a discovery signal, not a qualification.

Fewer than three approved matches

This page intentionally shows no supplier rows until at least three real reviewed records match. Try a related category.

APPROVED UGC PRODUCTS

Supplier-uploaded products

Only approved supplier submissions appear here. Pending, rejected and demo rows are excluded from public queries and sitemap output.

No approved supplier products in this combination yet

Browse the reviewed supplier profiles above or submit an RFQ. GetFRP does not fill empty categories with synthetic products.

Buyer FAQ

Need current factory evidence and quotations?

Send one controlled specification. GetFRP checks the matching public network without inventing supply records.

Submit an RFQ