EN 13706 Pultruded Profile Standard: Grades, Values and Testing
What EN 13706 covers, the E23 and E17 minimum property values, how profiles are designated and tested, and how to cite the standard in an RFQ to a Chinese pultruder.
EN 13706 is the European specification for pultruded fibre-reinforced plastic structural profiles. Part 1 covers designation, Part 2 test methods, tolerances and quality guidance, and Part 3 the minimum property values for two grades: E23, with a full-section modulus of at least 23 GPa, and E17, with at least 17 GPa. The 2002 editions were confirmed in December 2022 and remain current. A supplier's "EN 13706 compliant" claim is meaningful only with the grade and a test report on the offered profile, including the Annex D full-section modulus.
Editions: EN 13706-1, -2 and -3:2002, confirmed by CEN in December 2022 with no revision project open. Confirm the national adoption (for example BS EN or DIN EN) that the project names. Reviewed by GetFRP on .
Scope
- Pultruded structural profiles made of fibre-reinforced thermoset resin: I-beams, channels, angles, tubes, plates and similar constant sections.
- Part 1: designation, labelling and marking, including the reinforcement and matrix codes.
- Part 2: test methods, dimensional tolerances and guidance on quality assurance, including Annex D (full-section modulus) and Annex E (pin-bearing strength).
- Part 3: minimum property values for the E23 and E17 grades.
- Not covered: structural design. Design uses CEN/TS 19101:2022 in Europe or ASCE/SEI 74-23 in the United States; fire and chemical durability need separate requirements.
EN 13706-3 minimum property values by grade
| Property | E23 | E17 | Test method |
|---|---|---|---|
| Full-section modulus of elasticity (GPa) | 23 | 17 | EN 13706-2 Annex D |
| Tensile modulus, longitudinal (GPa) | 23 | 17 | EN ISO 527-4 |
| Tensile modulus, transverse (GPa) | 7 | 5 | EN ISO 527-4 |
| Tensile strength, longitudinal (MPa) | 240 | 170 | EN ISO 527-4 |
| Tensile strength, transverse (MPa) | 50 | 30 | EN ISO 527-4 |
| Pin-bearing strength, longitudinal (MPa) | 150 | 90 | EN 13706-2 Annex E |
| Pin-bearing strength, transverse (MPa) | 70 | 50 | EN 13706-2 Annex E |
| Flexural strength, longitudinal (MPa) | 240 | 170 | EN ISO 14125 |
| Flexural strength, transverse (MPa) | 100 | 70 | EN ISO 14125 |
| Interlaminar shear strength, longitudinal (MPa) | 25 | 15 | EN ISO 14130 |
Source: Fiberline Composites summary of EN 13706-3 (company source). Values are minimums; verify against the purchased standard text.
How an EN 13706 profile is designated
A full designation has the form EN 13706-E##-RF/MM. E## is the grade (E23 or E17), RF the reinforcement code (G for glass, C for carbon, A for aramid) and MM the matrix code (UP unsaturated polyester, VE vinyl ester, EP epoxy, PF phenolic). EN 13706-E23-G/VE therefore means an E23 glass and vinyl ester pultrusion.
Standard glass and polyester structural shapes from established pultruders reach E23. Flame-retardant formulations can fall short on a single property: Fiberline, for example, states that its grey fire-retardant profiles meet E23 except for a transverse tensile strength of 35 MPa.
What EN 13706 does not settle
The grade sets material minimums; it does not size a member. Deflection, buckling, connections and partial factors come from a design standard such as CEN/TS 19101:2022 or ASCE/SEI 74-23, which uses characteristic values calculated per ASTM D7290.
Fire reaction (EN 13501-1 or ASTM E84), UV and chemical exposure are separate requirements. State them for the actual wall thickness and resin system rather than relying on the grade.
EN 13706 and the Chinese standards
Chinese pultruders also test to GB/T 31539-2015, the national product standard for structural pultruded profiles. Its full-section compression test has since been published internationally as ISO 23930:2023. GB/T 31539 is the rough analogue of EN 13706, but the two specify different test panels and grades, so one report is not automatically accepted under the other.
GB 50608 is an engineering application standard for FRP in construction and should not be treated as a manufacturing equivalent to EN 13706. Where a supplier offers GB or ASTM data against an EN specification, ask for a written crosswalk and any non-equivalence.
How to cite it in an RFQ
- State the grade (E23 or E17) and the full designation, including reinforcement and matrix codes.
- Request the Annex D full-section modulus report and coupon results on the offered section, not catalogue typical values.
- Name the laboratory, the legal entity holding the report and the production site, and confirm they match the seller.
- Freeze drawings, dimensional tolerances and straightness, and the surfacing veil and UV package for outdoor use.
- Add fire class, chemical exposure and design basis (CEN/TS 19101 or ASCE/SEI 74) as separate requirements.
- Require batch records: glass content by loss on ignition and Barcol hardness as a cure check.
Sources
Requirements are paraphrased from public sources; the purchased standard text controls. See the editorial methodology.
- Fiberline Composites, the European standard EN 13706 explained Parts 1 to 3, E23 and E17 minimum values and test methods; flame-retardant grey profiles at 35 MPa transverse strength.
- GetFRP, China pultrusion market research (standards section) Edition status, CEN/TS 19101, ASCE/SEI 74-23, GB/T 31539-2015 and ISO 23930:2023, with source links.
- SAMR national standards registry Issue and implementation dates of GB/T 31539-2015 and related pultrusion standards.
Buying notes and qualification boundaries
A supplier statement that a profile is "to EN 13706" is incomplete without the grade and test evidence on the offered section. Ask for the full report, check the laboratory and legal entity, and confirm that the tested laminate matches production.
GetFRP lists reviewed Chinese supplier profiles that cite EN 13706 below. A citation is a discovery signal, not a qualification: the buyer still verifies the report scope, specimen orientation, conditioning and production link.
Matching supplier profiles
Each row shows the terms its public profile mentions. A match is a discovery signal, not a qualification.
Fewer than three approved matches
This page intentionally shows no supplier rows until at least three real reviewed records match. Try a related category.
Supplier-uploaded products
Only approved supplier submissions appear here. Pending, rejected and demo rows are excluded from public queries and sitemap output.
No approved supplier products in this combination yet
Browse the reviewed supplier profiles above or submit an RFQ. GetFRP does not fill empty categories with synthetic products.
Buyer FAQ
Both are minimum structural grades for pultruded profiles. E23 requires a full-section modulus of at least 23 GPa and higher strengths, for example 240 MPa longitudinal tensile strength against 170 MPa for E17. E17 suits lightly loaded or non-structural profiles; most structural specifications name E23.
Yes. EN 13706-1, -2 and -3:2002 were confirmed by CEN in December 2022 and had no revision project open at GetFRP's last review. Confirm the national adoption the project cites.
No. The standard sets material minimums for profiles. Member design, connections, fire and durability need a design standard such as CEN/TS 19101 or ASCE/SEI 74 and project-specific requirements.
Not automatically. GB/T 31539-2015 is the closest Chinese analogue, but test panels and grades differ. Ask for EN 13706 testing on the offered section, or a written engineering crosswalk that the project engineer accepts.
The grade and designation, the Annex D full-section modulus report, coupon test results, the laboratory and report holder, drawings and tolerances, and batch glass-content and Barcol records.
Related searches
Need current factory evidence and quotations?
Send one controlled specification. GetFRP checks the matching public network without inventing supply records.